Discussion on the Method of the Disconnecting Test on Internal Fuses
摘要
根据IEC标准和国家标准对电力电容器用内部熔丝隔离试验的要求
指出了现行试验方法中存在的不足之处。提出了一种新的试验方法
经实际验证表明具有符合标准、符合产品运行实际且简单易行的特点。
Abstract
The article points out the shortcomings of present disconnecting test method on internal fuses
according to the requirements of IEC and China standards on internal fuses used for power capacitors.A new kind of disconnecting test method on internal fuses is proposed.This new test method has been proved by practice.It conforms to standards and practical operation and is also simple to use.