LIANG CONG. Estimating the Initial Value of the Unbalance Protection for Shunt Capacitor Bank. [J]. Power capacitor & reactive power compensation, 2002, (3): 1-4.
LIANG CONG. Estimating the Initial Value of the Unbalance Protection for Shunt Capacitor Bank. [J]. Power capacitor & reactive power compensation, 2002, (3): 1-4.DOI:
Estimating the Initial Value of the Unbalance Protection for Shunt Capacitor Bank
摘要
通过对开口三角电压保护信号初始值大小的估算、分析
对并联电容器组不平衡保护的安全性进行探讨
提出了并联电容器组内部故障不平衡保护初始不平衡测量值估算式。
Abstract
By estimating and analyzing the initial value of the open delta voltage signal
investigation is made into the safety of the unbalance protection for the shunt capacitor bank. An expression is put forward for estimating the initial measured value of the unbalance protection for shunt capacitors.