FU JUN ET AL. Partial Discharge Measurement Under DC Voltage for DC—Filter Capacitors. [J]. Power capacitor & reactive power compensation, 1993, (3): 22-24.
FU JUN ET AL. Partial Discharge Measurement Under DC Voltage for DC—Filter Capacitors. [J]. Power capacitor & reactive power compensation, 1993, (3): 22-24.DOI:
Partial Discharge Measurement Under DC Voltage for DC—Filter Capacitors
Ln order to help the analysis of the damage causes for the filter capacitors installed in GZB converter station
the tests of partial discharge under DC voltage for the capacitors were performed under normal and high temperature conditions using two—arm connection and microwindow circuit to suppress the interference. The results show that the DC partial discharges of the capacitors under normal temperature don’t have any apparent development under high temperature. The paper also discusses some problems about the DC partial discharge measurement for capacitors.