DONG Xiaoliang. Correlation Analysis Between Quality of DC-link Capacitor Element and Winding Tension Control[J]. Power capacitor & reactive power compensation, 2025, 46(4): 40-48.
DOI:
DONG Xiaoliang. Correlation Analysis Between Quality of DC-link Capacitor Element and Winding Tension Control[J]. Power capacitor & reactive power compensation, 2025, 46(4): 40-48. DOI: 10.14044/j.1674-1757.pcrpc.2025.04.005.
Correlation Analysis Between Quality of DC-link Capacitor Element and Winding Tension Control
Metallized capacitors are widely used in VSC-HVDC transmission field due to such features of the metallized film as self-healing property
high operating field strength and high energy density. The key to the quality of its elements is in the the accuracy of the winding process
with the control of winding tension in particular
which will directly affect the interlayer contact condition and the radial pressure distribution of the film. Insufficient tension can lead to looseness between layers and introduce air gaps
while excessive tension can damage the film and affect the self-healing performance. Staring from the tension adjustment in this paper
the influence mechanism of the winder on the element structure and self-healing characteristics is analyzed
and the concept of interlayer pressure is introduced to explore its influence on self-healing performance
providing theoretical basis for optimizing design and setting process parameters.