直流输电线路在雷击工况下,会引起换流站中性区域产生过电压,极大的影响和威胁中性区域设备特别是直流滤波器安全稳定运行。文章针对某±500 kV换流站直流双极大地回线全压运行方式极ⅡHP12/36直流滤波器典型故障过电压及其特性,搭建电磁暂态仿真模型开展过电压特性研究,得出该过电压是介于工频过电压和操作过电压之间的非标准类工频过电压的结论,并结合这一论断,分析了爬距计算电压、雷电耐受电压和操作耐受电压等因素对过电压的影响,提出了直流滤波器及其支柱绝缘子设备选型要求,对滤波器、避雷器暂态额定值选择、关键参数优化具有参考和借鉴意义。
Under lightning strike conditions,direct current transmission lines can cause overvoltage in the neutral area of converter station,greatly affecting and threatening the safe and stable operation of equipment(with DC filters in particular)of neutral area. In this paper an electromagnetic transient simulation model is set up to investigate overvoltage characteristics,fousing on a typical fault overvoltage event and its properties in the pole II HP12/36DC filter in the full-voltage operation mode of the DC bipolar ground return system at a ±500 kV converter station. It is concluded that the overvoltage is a non-standard type of power frequency overvoltage between power frequency overvoltage and operating overvoltage. Based on this conclusion,the influence of such factors as creepage distance calculated voltage,lightning withstand voltage and operating withstand voltage on overvoltage is analyzed,The type selection requirements for DC filters and their supporting insulator are proposed. This has reference and inspiration value for the selection of transient rated values and key parameter optimization of filters and lightning arresters.
戈尔德,周诗,孙景群.雷电[M].北京:电力工业出版社,1982.
张耀月. ±800 kV直流分压器低能量放电故障分析[J].电力电容器与无功补偿,2025,46(1):98-105.
ZHANG Yaoyue. Analysis on low energy discharge fault analysis of ±800 kV DC voltage divider[J]. Power Capacitor& Reactive Power Compensation,2025,46(1):98-105.
张宏伟.振荡过电压对双极中性线滤波器电抗器绝缘性能影响分析[J].电力电容器与无功补偿,2025,46(5):74-84.
ZHANG Hongwei. Analysis of the Influence of oscillatory overvoltage on the insulation performance of bipolar neutral line filter reactors[J]. Power Capacitor & Reactive Power Compensation,2025,46(5):74-84.
LI Xin,WANG Yang,XU W. A new filtering scheme for HVDC terminals based on damped high-pass filter[J]. IEEE Transactions on Power Delivery,2019,34(5):2050-2057.
张宏伟,杨晓静,姬凯.暂态过电压对双极中性线冲击电容器绝缘性能影响分析[J].电力电容器与无功补偿,2025,46(3):61-68.
ZHANG Hongwei,YANG Xiaojing,JI Kai. Analysis on influence of transient overvoltage on insulation performance of bipolar neutral line surge capacitor[J]. Power Capacitor& Reactive Power Compensation,2025,46(3):61-68.
吴钰颖,郭洁. ±1100 kV直流滤波器典型故障过电压特性研究[J].电力工程技术,2020,39(1):130-137.
WU Yuying,GUO Jie. Typical fault overvoltage characteristics of ±1100 kV DC filter[J]. Jiangsu Electrical Engineering,2020,39(1):130-137.
江金成,彭寅章,王尚德,等.特高压换流站交流滤波电容器组不平衡保护定值整定研究[J].电力电容器与无功补偿,2025,46(2):98-105.
JIANG Jincheng,PENG Yinzhang,WANG Shangde,et al. Study on unbalance protection setting of AC filter capacitor bank in UHV converter station[J]. Power Capacitor & Reac tive Power Compensation,2025,46(2):98-105.
张宏伟.内部异物对超高压HGIS隔离开关触头放电影响分析[J].农村电气化,2025(6):48-55.
ZHANG Hongwei. Analysis of the influence of internal foreign objects on the discharge of ultra-high voltage HGIS disconnector contacts[J]. Rural Electrification,2025(6):48-55.
熊俊,甘文风,陈愚,等.受端电网故障下真双极柔性直流输电系统电压协同控制方法[J].电网与清洁能源,2024,40(5):32-41.
XIONG Jun,GAN Wenfeng,CHEN Yu,et al. A voltage collaborative control method for symmetrical bipolar MMCHVDC under the receiving-end grid fault[J]. Power System and Clean Energy,2024,40(5):32-41,
王运超,余占清,牟亚,等.特高压直流中性母线过电压特性及抑制措施[J].中国电机工程学报,2019,39(22):6765-6773.
WANG Yunchao,YU Zhanqing,MU Ya,et al. Neutral bus overvoltage characteristics and suppression measures for UHVDC converter stations[J]. Proceedings of the CSEE,2019,39(22):6765-6773.
ZHU Xiaoguang,LIU Yichen,DENG Junbo,et al. Study on overvoltage characteristics and arrester configuration strategy for ±1100 kV HVDC transmission lines[J]. The Journal of Engineering,2019(16):1232-1237.
±800 kV高压直流输电系统成套设计规程:DL/T 5426—2021[S]. 2021.
Systemdesi gnstandard for ±800 kV HVDC system:DL/T 5426—2021[S]. 2021.
高压直流换流站设计规范:GB/T 51200—2016[S]. 2016. Code for design of HVDC converter station:GB/T 51200—2016[S]. 2016.
王剑,谷山强,彭波,等.国网辖区特高压直流线路防雷运行现状分析[J].全球能源互联网,2018,1(4):511-520.
WANG Jian,GU Shanqiang,PENG Bo,et al. Research on lightning protection operation status of UHVDC transmission lines inSGCC[J]. Journal of Global Energy Interconnection,2018,1(4):511-520.
龚大卫,俞敦耀.三峡至常州±500 kV高压直流输电工程简介[J].中国电力,2000,33(2):42-44,53.
GONG Dawei,YU Dunyao. A brief introduction to ±500 kV HVDC transmission project from the Three Gorges to Changzhou[J]. Electric Power,2000,33(2):42-44,53.
刘泽洪. ±1100 kV特高压直流输电工程创新实践[J].中国电机工程学报,2020,40(23):7782-7791.
LIU Zehong. Findings in development of±1100 kV UHVDC transmission[J]. Proceedings of the CSEE,2020,40(23):7782-7791.
邓京,韩永霞,邓俊文,等. ±800 kV换流站交流滤波器绝缘配合影响因素[J].广东电力,2021,34(5):107-113.
DENG Jing,HAN Yongxia,DENG Junwen,et al. Influencing factors of insulation coordination of AC filter in±800 kV converter station[J]. Guangdong Electric Power,2021,34(5):107-113.
DAI Zhihui,LIU Ningning,ZHANG Cheng,et al. A pilot protection for HVDC transmission lines based on transient energy ratio of DC filter link[J]. IEEE Transactions on Power Delivery,2020,35(4):1695-1706.
ASIF M,LEE H Y,KHAN U A,et al. Analysis of transient behavior of mixed high voltage DC transmission line under lightning strikes[J]. IEEE Access,2019(7):7194-7205.
VAN JAARSVELD B J,NICOLAE D V. Simplified modelling of an air-core reactor for lightning impulse transient studies[J]. International Journal of Electrical Power & Energy Systems,2017,92(1):83-92.
高压直流输电系统用直流滤波电容器及中性母线冲击电容器:GB/T 20993—2012[S]. 2012.
DC filter capacitors and neutral bus surge capacitors for HVDC transmission system:GB/T 20993—2012[S]. 2012.
XUE Ancheng,YUE Lei,ZHANG Jiahuan,et al. A new quantitative analysis method for overvoltage in sending end electric power system with UHVDC[J]. IEEE Access,2020(8):145898-145908.
绝缘配合:GB 311.1—2012[S]. 2012. Insulation co-ordination:GB 311.1—2012[S]. 2012.
曹虹,周泽昕,吕鹏飞,等.高压直流输电线路故障初始阶段解析方法研究[J].电力系统及其自动化学报,2022,34(7):137-147.
CAO Hong,ZHOU Zexin,LYU Pengfei,et al. Study on analysis method for HVDC transmission line faults at initial stage[J]. Proceedings of the CSU-EPSA,2022,34(7):137-147.
雷梦飞,王少华,刘黎,等.特高压直流输电线路雷击故障特性分析[J].电瓷避雷器,2019(3):57-62.
LEI Mengfei,WANG Shaohua,LIU Li,et al. Analysis on lightning fault characteristics of UHVDC transmission line [J]. Insulators and Surge Arresters,2019(3):57-62.
输变电设备状态检修试验规程:Q/GDW 1168—2013[S]. 2020.
± 800 kV特高压直流设备预防性试验规程:Q/GDW 10299—2025[S]. 2025.
张耀月.伞裙结构对超(特)高压电流互感器闪络特性影响的研究[J].电力安全技术,2024,26(12):73-78.
ZHANG Yaoyue. Study on influence of umbrella-skirt structure upon the flashover characteristics of UHV current transformer[J]. Electric Safety Technology,2024,26(12):73-78.
聂男峰,王磊,王东举,等. ±800 kV特高压多端直流系统换流阀过电压机理及影响因素研究[J].电网技术,2020,44(1):307-315.
NIE Nanfeng,WANG Lei,WANG Dongju,et al. Study on overvoltage mechanism and influencing factors of converter valves in ±800 kV multi-terminal UHVDC system[J]. Power System Technology,2020,44(1):307-315.
高压直流输电系统直流滤波器:GB/T 25308—2022[S]. 2022.
DC filters for high voltage direct current(HVDC)transmission system:GB/T 25308—2022[S]. 2022.
LIU Zehong,ZHANG Fuxuan,YU Jun,et al. Research on key technologies in ±1100 kV ultra-high voltage DC transmission[J]. High Voltage,2018,3(4):279-288.
0
Views
0
下载量
0
CSCD
0
CNKI被引量
Publicity Resources
Related Articles
Related Author
Related Institution
陕公网安备 61010402000197