Analysis and Prevention of Short Circuit Fault in 35 kV Shunt Capacitor Bank
- 35 kV并联电容器组短路故障分析及预防
- Vol. 47, Issue 3, Pages: 1-9(2026)
DOI:10.14044/j.1674-1757.pcrpc.2026.03.001
移动端阅览


浏览全部资源
扫码关注微信
State Grid Henan Electrical Power Company, Zhengzhou 450000, China
State Grid Henan Extra High Voltage Company, Zhengzhou 450000, China
Nissin Electric(Wuxi)Co., Ltd., Jiangsu Wuxi 214000, China
Received:16 January 2026,
Revised:2026-02-25,
Published:25 June 2026
移动端阅览
HU Runge, KE Chong, LYU Jie, et al. Analysis and Prevention of Short Circuit Fault in 35 kV Shunt Capacitor Bank[J]. Power Capacitor & Reactive Power Compensation, 2026, 47(3): 1-9.
HU Runge, KE Chong, LYU Jie, et al. Analysis and Prevention of Short Circuit Fault in 35 kV Shunt Capacitor Bank[J]. Power Capacitor & Reactive Power Compensation, 2026, 47(3): 1-9. DOI: 10.14044/j.1674-1757.pcrpc.2026.03.001.
针对500 kV某变电站35 kV并联电容器组因外绝缘受损导致的起火烧毁故障情况,依据现场检查、故障录波波形分析及典型特征电容器的解体检查,推断C相电容器组右下桥臂区域电容器因绝缘子受潮经汇流铝排对金属框架电弧放电,逐步发展至B相,导致B相右下框架电弧灼伤,进而造成B相、C相相间短路。此时,电容器三相参数不一致,录波电流波形中可见明显变化。故障持续发展,高温及畸变电场作用下电容器组三相短路,起火烧毁。针对本次故障暴露出的问题,提出了加强运行十年以上并联电容器组设备巡视,关注红外热像检测,建立设备消缺管理档案等改进预防措施。
Regarding the fire-induced burnout fault of a 35 kV shunt capacitor bank at a 500 kV substation due to the damage of its external insulation,an investigation is carried out based on on-site inspections, analysis of record oscillogram,and the disassembly inspection of a typical characteristic capacitor. It is deduced that in the lower right arm region of the phase C capacitor bank,a capacitor unit experiences arc discharge from an insulator(due to moisture absorption)via the aluminum busbar to the metal frame. This discharge gradually developes into the phase B,causing arc burns on the lower right frame of phase B,and ultimately resulting in a phase-to-phase short circuit between phase B and phase C. At this time,the three-phase parameters of the capacitor are inconsistent,and obvious changes can be observed in the recorded current oscillogram. The fault continues to develop,the three phases of the capacitor bank is short-circuited under the action of high temperature and distorted electric field,and then burn out. To address the issues revelaed by this fault,such preventive measures as enhance routine inspection of shunt capacitor banks that have been in service for over ten years,priortize infrared thermography monitoring and set up an management archive for equipment defect elimination are proposed.
张全元.变电运行一次设备现场培训教材[M].北京:中国电力出版社,2010.
王玉荣,李方兴,陈昊.基于补偿设备混合配置策略的电力系统无功规划[J]. 东南大学学报(自然科学版), 2017,47(2):299-305.
WANG Yurong,LI Fangxing,CHEN Hao. Reactive power planning using different VAr devices[J]. Journal of South-east University(Natural Science Edition),2017,47(2):299-305.
魏鑫.高压电力电容器故障原因分析与保护研究[D].大连:大连理工大学,2015.
王书征,赵洋,李沛林,等.考虑电压-无功调节的台区互联装置规划方法[J].电力工程技术,2024,43(3):111-120.
WANG Shuzheng,ZHAO Yang,LI Peilin,et al. Planning method of station area interconnection device considering voltage-reactive power regulation[J]. Electric Power Engineering Technology,2024,43(3):111-120.
杨结春,龙玉萍,秦华忠,等. HVDC用斜撑塔电力电容器组加工和安装方法研究[J].电力电容器与无功补偿, 2025,46(1):1-6.
YANG Jiechun,LONG Yuping,QIN Huazhong,et al. Research on processing and installation method of inclined-sup-port-tower power capacitor bank for HVDC application[J]. Power Capacitor & Reactive Power Compensation,2025, 46(1):1-6.
王珺,朱亮,高晶,等.基于多维特征参量的台区拓扑识别方法研究[J].浙江电力,2024,43(12):114-121.
WANG Jun,ZHU Liang,GAO Jing ,et al. Research on a to-pology identification method for distribution areas using multi-dimensional electrical characteristic parameters[J].浙江电力,2024,43(12):114-121.
王飞,唐静.基于Electron的油浸式变压器状态评价系统的设计与实现[J].变压器,2024,61(1):24-28.
WANG Fei,TANG Jing. Design and implementation of oilimmersed transformer condition evaluation system based on electron [J]. Transformer,2024,61(1):24-28.
郭磊,张朝峰,胡润阁,等.一起换流站交流滤波器电阻器烧蚀故障分析[J].电力电容器与无功补偿,2025,46(3):45-50.
GUO Lei,ZHANG Chaofeng,HU Runge,et al. Ablation analysis of ac filter resistor in a converter station[J]. Power Capacitor & Reactive Power Compensation,2025,46(3):45-50.
吴小忠,甘星,严亚兵,等.基于过热故障仿真的高压开关柜测温点优化方法[J].西安工程大学学报,2025,39(6):128-138.
WU Xiaozhong,GAN Xing,YAN Yabing,et al. Optimization method of high-voltage switchgear temperature measurement points based on overheating fault simulation[J]. Journal of Xi'an Polytechnic University,2025,39(6):128-138.
刘天宇,车传强,赵磊,等. 35 kV真空断路器开断并联电容器过电压分析[J].东北电力技术,2024,45(5):34-36.
LIU Tianyu,CHE Chuanqiang,ZHAO Lei,et al. Analysis of overvoltage of 35 kV vacuum circuit breaker breaking parallel capacitors[J]. Northeast Electric Power Technology,2024,45(5):34-36.
刘斌,岳永刚,张庆如,等.基于串联非线性电阻组合开关的补偿电容器组投切重燃过电压研究[J].高压电器, 2024,60(8):183-192.
LIU Bin,YUE Yonggang,ZHANG Qingru,et al. Research on switching reignition over-voltage of compensation capacitor bank based on series nonlinear resistor combination switch[J]. High Voltage Apparatus,2024,60(8):183-192.
吴诚威,张居宁,朱晓光,等.投切并联电容器时真空断路器连续重燃事故的机理分析[J].高压电器,2024,60(6):181-187.
WU Chengwei,ZHANG Juning,ZHU Xiaoguang,et al. Mechanism analysis of sustaining reignition of vacuum circuit breaker in shunt capacitor switching[J]. High Voltage Apparatus,2024,60(6):181-187.
李冠华,徐凯,栗罡,等. 66 kV系统消弧线圈分散式补偿策略研究[J].高压电器,2024,60(12):103-112.
LI Guanhua,XU Kai,LI Gang,et al. Research on distributed compensation strategy of arc suppression coil of 66 kV system[J]. High Voltage Apparatus,2024,60(12):103-112.
华涛,韩翊,井巍,等.一起35 kV电容器组串联电抗器起火事故分析及处理[J].山东电力高等专科学校学报, 2021,24(2):17-19.
HUA Tao,HAN Yi,JING Wei,et al. Analysis and treatment of a fire accident of 35 kV capacitor bank series reactor[J]. Journal of Shandong Electric Power College,2021, 24(2):17-19.
交流电气装置的过电压保护和绝缘配合设计规范:GB/T 50064—2014[S].2014.
Code for design of overvoltage protection and insulation coordination for AC electrical installations:GB/T 50064—2014[S]. 2014.
330 kV~750 kV变电站无功补偿装置设计技术规定:DL/T 5014—2010[S]. 2010.
Technical rules for designing of reactive power compensation equipment in 330~750 kV substations:DL/T 5014—2010[S]. 2010.
常菊民,王薇,高小根.单星形桥式差流保护的公式推导与分析[J].电力电容器与无功补偿,2008,29(6):12-14.
CHANG Jumin,WANG Wei,GAO Xiaogen. The deduce and introduction to the protection formula of the unbalance current bridge in single-star connection[J]. Power Capacitor & Reactive Power Compensation,2008,29(6):12-14.
董万光,董亚,侯宪法,等.一起35 kV并联电容器组群爆事故原因分析[J].电力电容器与无功补偿,2013,34(5):71-74.
DONG Wanguang,DONG Ya,HOU Xianfa,et al. Analysis of a colony fusing failure in 35 kV shunt capacitor bank[J]. Power Capacitor & Reactive Power Compensation,2013, 34(5):71-74.
韩少卫,姚晖,苏建明,等.一起10 kV并联电容器组断路器异常跳闸分析[J].电力电容器与无功补偿,2015, 36(4):18-21.
HAN Shaowei,YAO Hui,SU Jianming,et al. Analysis on abnormal tripping of circuit breaker in 10 kV shunt capacitor bank[J]. Power Capacitor & Reactive Power Compensation,2015,36(4):18-21.
电气绝缘用薄膜第4部分:聚脂薄膜:GB/T 13542.4—2009[S]. 2009.
Film for electrical insulation—Part 4:Polythylene terephthalate film used for electrical insulation:GB/T 13542.4—2009[S]. 2009.
张广东,温定筠,汪沨,等.基于EMTP/ATP的35 kV并联电容器组内部过电压研究[J].电力电容器与无功补偿, 2017,38(1):45-49.
ZHANG Guangdong,WEN Dingjun,WANG Feng,et al. Study on internal overvoltage of 35 kV capacitors bank based onEMTP/ATP[J]. Power Capacitor & Reactive Power Compensation,2017,38(1):45-49.
张晓新,董灵斌,林峰,等.自取电的电缆故障类型及故障分段定位的研究[J].高压电器,2024,60(11):116-122.
ZHANG Xiaoxin,DONG Lingbin,LIN Feng,et al. Research on fault types and fault segment location of self-feeding cable[J]. High Voltage Apparatus,2024,60(11):116-122.
陈琳,张文海,肖先勇,等.基于波形相似度的中压配电网瞬时故障重复性辨识[J].电测与仪表,2025,62(7):106-116.
CHEN Lin,ZHANG Wenhai,XIAO Xianyong,et al. Waveform similarity-based recurrent temporary fault identification in a medium-voltage distribution network[J]. Electrical Measurement & Instrumentation,2025,62(7):106-116.
马飞越,马青,崔巍,等.宁夏电网35 kV电容器组关合涌流计算与仿真分析[J].宁夏电力,2024(4):41-48.
MA Feiyue,MA Qing,CUI Wei,et al. Calculation and simulation analysis of closing surge currents in 35 kV capacitor banks in the Ningxia power grid[J]. Ningxia Electric Power,2024(4):41-48.
王雪松,岳永刚,吕鑫,等.基于串联电阻开关的电容器组投切重燃过电压仿真研究[J].电力电容器与无功补偿,2024,45(4):124-132.
WANG Xuesong,YUE Yonggang,LYU Xin,et al. Research on simulation of switching re-ignition over-voltage of capacitor bank based on series resistance switch[J]. Power Capacitor & Reactive Power Compensation,2024,45(4):124-132.
邓于可,唐金叶,卢金钊,等.特高压换流站交流滤波器电容器发热故障研究[J].电力电容器与无功补偿,2025, 46(1):16-22.
DENG Yuke,TANG Jinye,LU Jinzhao,et al. Study on heating failure of AC filter capacitor at UHV converter station[J]. Power Capacitor & Reactive Power Compensation, 2025,46(1):16-22.