国网新疆电力有限公司昌吉供电公司,新疆 昌吉 831100
何龙(1988—),男,高级工程师,主要从事高压电气设备故障诊断研究工作。E-mail:helong69@126.com。
朱咏明(1973—),男,高级工程师,主要从事电气设备智能化、数字化工作。
马金财(1975—),男,本科,主要从事变电高压设备状态检修、故障诊断工作。E-mail:860731525@qq.com。
收稿日期:2024-05-07,
纸质出版日期:2025-04-25
移动端阅览
何龙, 朱咏明, 马金财, 等. 基于PCP和改进CNN的变压器内外故障诊断方法研究[J]. 电力电容器与无功补偿, 2025,46(2):106-119.
HE Long, ZHU Yongming, MA Jincai, et al. Research on Fault Diagnosis Method Inside and Outside Transformer Based on PCP and Improved CNN[J]. Power capacitor & reactive power compensation, 2025, 46(2): 106-119.
何龙, 朱咏明, 马金财, 等. 基于PCP和改进CNN的变压器内外故障诊断方法研究[J]. 电力电容器与无功补偿, 2025,46(2):106-119. DOI: 10.14044/j.1674-1757.pcrpc.2025.02.013.
HE Long, ZHU Yongming, MA Jincai, et al. Research on Fault Diagnosis Method Inside and Outside Transformer Based on PCP and Improved CNN[J]. Power capacitor & reactive power compensation, 2025, 46(2): 106-119. DOI: 10.14044/j.1674-1757.pcrpc.2025.02.013.
为了有效防止变压器差动继电器在非故障瞬态情况下的误动,提出了一种区分变压器内部、外部故障及其暂态过程的快速辨识方法。首先,针对工程现场监测数据可能包含噪声的问题,提出一种利用平行坐标图(PCP)对三相差动时间序列图像化的方法,将三相时间序列可视化,容纳了故障所有信息的同时保障了信号的抗噪性;其次,对卷积神经网络(CNN)加以改进:在特征提取部分增加ECA注意力机制模块,再利用优化后的多核支持向量机对CNN自带Softmax分类器进行改进,增强CNN对各类故障场景分类的适用性,并与实现变压器内外故障的诊断与辨识;最后,搭建变压器内部和外部故障仿真模型,获取绕组匝间故障、接线故障以及励磁涌流、电流互感器(CT)饱和铁磁谐振等故障时差动保护监测数据,据此构建图像化故障样本集,对论文所提方进行验证,并与同类算法进行对比,证明所提方法的优越性。
In order to effectively prevent the maloperation of transformer differential relays in non fault transient conditions
a kind of fast identification method to distinguish internal and external faults and their transient processes in transformers is proposed. Firstly
a method to visualize the three-phase differential time series is proposed by using parallel coordinate plot (PCP) to address the issue of potential noise in on-site monitoring data
which
at the same time of containing all fault information
ensures signal noise resistance. Secondly
improvements are made to the CNN: an ECA attention mechanism module is added to the feature extraction section
and the optimized multi kernel support vector machine is used to improve the softmax classifier of the convolutional neural network (CNN)
enhancing the applicability of CNN to various fault scenarios classification and facilitating the diagnosis and identification of internal and external faults in transformers. Finally
a internal and external fault simulation model of transformer is set up to obtain such differential protection monitoring data as winding inter turn faults
wiring faults
excitation inrush currents
current transformer (CT) saturation ferromagnetic resonance and other faults. Based on this
a graphical fault sample set is set up
the proposed method in this paper is verified and compared with similar algorithms so to prove the superiority of the proposed method.