ZHAO WEI-DONG. Calculation and Adjustment on the Unbalance Neutral Electric Current Y-Y Connected Capacitors. [J]. Power capacitor & reactive power compensation, 2010, 31(5): 14-18.
ZHAO WEI-DONG. Calculation and Adjustment on the Unbalance Neutral Electric Current Y-Y Connected Capacitors. [J]. Power capacitor & reactive power compensation, 2010, 31(5): 14-18. DOI: 10.14044/j.1674-1757.pcrpc.2010.05.004.
Calculation and Adjustment on the Unbalance Neutral Electric Current Y-Y Connected Capacitors
摘要
针对双星形接线方式电容器组中性点不平衡电流在实际运行维护中存在的问题进行理论分析
确定出产生中性点不平衡电流的主要因素
提出减少不平衡电流的改进措施和方法
推导出双星形电容器组中性点不平衡电流的计算公式。实践表明
根据优化计算指导电容器组的调整或更换
可以显著降低中性点不平衡电流
减少电容器调整的盲目性。
Abstract
According to the problems on the unbalance neutral current in Y-Y connected capacitors during actual operation and maintenance
the theoretical analysis is made to define the major factor on the unbalance neutral current
propose the improvement measures and methods to reduce unbalance neutral current and deduce the calculation formula on unbalance neutral current in Y-Y connected capacitors.It is shown in practices that the adjustment or replacement of capacitor bank instructed in accordance with optimization calculation can reduce significantly the unbalance neutral current and decrease the adjustment times of capacitors.