SHENG GUO-ZHAO, LIN HAO, YAN FEI, et al. Imbalance Protection Calculation on High Voltage Shunt Capacitor Bank with Internal Fuse and Asymmetric Wiring. [J]. Power capacitor & reactive power compensation, 2013, 34(6): 60-65.
SHENG GUO-ZHAO, LIN HAO, YAN FEI, et al. Imbalance Protection Calculation on High Voltage Shunt Capacitor Bank with Internal Fuse and Asymmetric Wiring. [J]. Power capacitor & reactive power compensation, 2013, 34(6): 60-65. DOI: 10.14044/j.1674-1757.pcrpc.2013.06.013.
Imbalance Protection Calculation on High Voltage Shunt Capacitor Bank with Internal Fuse and Asymmetric Wiring
摘要
本文给出不对称接线大容量内熔丝高压并联电容组中性线不平衡电流保护和桥式差电流保护的通用计算公式
为基层电力部门提供了一种简便的计算方法。通过对称接线和不对称接线桥式差电流保护计算结果的比较
分析对称接线计算结果替代不对称接线桥式差电流保护计算结果的可能性
60 Mvar以上的并联电容器组的不平衡保护替代计算引起的误差小于2%。
Abstract
In this paper
an universal formula for calculating the neutral line current imbalance protection and bridge differential current protection in large-capacity high voltage shunt capacitor bank with internal fuse and asymmetric wiring is introduced
which provides a simple method for the grassroots power sector. Throughout comparison of protection calculation of symmetrical and asymmetrical wiring bridge differential current
possibilities of adopting current protection calculation results with symmetrical wiring to replace asymmetrical wiring is analyzed. The imbalance protection error caused by the new calculation for shunt capacitors bank above 60 Mvar is less than 2%.