PANG YONGGANG. Analysis and Comparison of Reactive Power Compensation Methods for Submerged Arc Furnace. [J]. Power capacitor & reactive power compensation, 2015, 36(1): 21-25.
PANG YONGGANG. Analysis and Comparison of Reactive Power Compensation Methods for Submerged Arc Furnace. [J]. Power capacitor & reactive power compensation, 2015, 36(1): 21-25. DOI: 10.14044/j.1674-1757.pcrpc.2015.01.005.
Analysis and Comparison of Reactive Power Compensation Methods for Submerged Arc Furnace
摘要
对矿热炉的补偿方式进行了理论分析
分析了各种补偿方式的利弊。并通过实例计算分析
从投资与回报
入炉功率以及节能等各方面进行了全面的分析比较
说明串联补偿是目前最好的补偿方式
使用串联补偿可在提高产能的同时
可节约电能消耗
提高企业的经济效益。
Abstract
In this paper
through theoretical analysis of compensation for submerged arc furnace
the advantages and disadvantages of various compensation methods are stated. Based on an example calculation and analysis
it is showed that the series compensation is the best way of compensation from the aspects of the investment and return
the power into furnace and energy saving and so on. If the series compensation is used it will be effectively improve the productivity and greatly save power
and improve the economic efficiency of enterprises.