摘要
介绍了高压直流输电工程交流滤波器电容器本体保护配置概况。针对1起滤波器跳闸事故
分析电容器故障过程中表现出的非典型特征
通过对该电容器进行深度解剖
找出了此次故障的原因
针对暴露出的问题进行了分析探讨
对交流滤波器电容器的设计及运行维护工作有一定的参考意义。
Abstract
In this paper
the protection disposition of AC filter capacitor body for HVDC transmission project is introduced. As for one tripping accident of filter
the typical feature shown in the capacitor fault is analyzed and
throughout deep analysis of the capacitor
the reason of the fault is found. The exposed problem is analyzed and discussed
which has a definite reference significance to the design and maintenance of AC filter capacitor.