HU HAINING, GONG MIAO. Influence of Harmonic Sequence Impedance and Reactive Power Compensation Capacitor on Power Quality in Distribution Grid. [J]. Power capacitor & reactive power compensation, 2016, 37(6): 70-75.
HU HAINING, GONG MIAO. Influence of Harmonic Sequence Impedance and Reactive Power Compensation Capacitor on Power Quality in Distribution Grid. [J]. Power capacitor & reactive power compensation, 2016, 37(6): 70-75. DOI: 10.14044/j.1674-1757.pcrpc.2016.06.013.
Influence of Harmonic Sequence Impedance and Reactive Power Compensation Capacitor on Power Quality in Distribution Grid
摘要
谐波电流注入电网会在系统中感应出谐波阻抗
获取谐波阻抗是一世界性难题
本文针对上海地区0.4 k V配电网的特点
采用了傅里叶级数展开法及叠加定理论证了电能质量分析仪的现场实测结果
尝试分析基于配电网的各种运行方式下及无功补偿电容器各种投切方式下的三相谐波正序、负序、零序阻抗
并由谐波序阻抗进一步分析谐波对配电网电能质量的污染程度。
Abstract
Injection of harmonic current into power grid will induce harmonic impedance in the power system and the acquisition of harmonic impedance is a worldwide problem. In this paper
the site experimental result of power quality analyzer
according to the feature of 0.4 k V distribution grid in Shanghai
is demonstrated by the use of Fouries series expansion and superposition theorem. The positive sequence
negative sequence and zero sequence impedance of three-phase harmonics based on various operation modes of distribution grid and various switching modes of reactive power compensation cap-acitor are analyzed. And the pollution level of harmonic to the power quality of distribution grid is analyzed further by the harmonic sequence impedance.
关键词
谐波序阻抗励磁阻抗无功补偿容抗
Keywords
harmonic sequence impedanceexciting impedancereactive power compensationcapacitive impedance