ZHU JIANHUA, XU GANGGANG, LIU PENGFEI, et al. Selection Advice on Grounding and Reactance Ratio of Shunt Capacitor. [J]. Power capacitor & reactive power compensation, 2017, 38(5): 7-11.
ZHU JIANHUA, XU GANGGANG, LIU PENGFEI, et al. Selection Advice on Grounding and Reactance Ratio of Shunt Capacitor. [J]. Power capacitor & reactive power compensation, 2017, 38(5): 7-11. DOI: 10.14044/j.1674-1757.pcrpc.2017.05.002.
Selection Advice on Grounding and Reactance Ratio of Shunt Capacitor
摘要
针对并联电容器组设计和施工中出现的电抗率和接地配置不当的问题
提出了串联电抗器以外的部件接地应考虑距离串联电抗器的距离原则
以及电抗率应根据接入电网的背景谐波、变压器绕组接线方式、绕组负荷情况进行配置
并针对实际情况进行了分类以及相应的配置方法。
Abstract
As for the issue of inappropriate reactance ratio and grounding configuration which is occurredin the design and construction of shunt capacitor bank
the principle of considering distance to the serialreactor for the grounding of the parts which is outside of the serial reactor is proposed. And the reactanceratios shall be configured as per the background harmonics of the connected grid
the wiring mode of thetransformer winding and situation of the winding load and classification and corresponding configurationmethod are made in accordance with the actual situation.
关键词
串抗率背景谐波双接地三角型接线
Keywords
series reactance ratiobackground harmonicsdouble groundingdelta connection