LI HUI, LI SHENG, XU WEI, et al. Batch Testing Method of Sub Module of STATCOM. [J]. Power capacitor & reactive power compensation, 2018, 39(3): 70-74.
LI HUI, LI SHENG, XU WEI, et al. Batch Testing Method of Sub Module of STATCOM. [J]. Power capacitor & reactive power compensation, 2018, 39(3): 70-74. DOI: 10.14044/j.1674-1757.pcrpc.2018.03.013.
as an important flexible AC transmission system(FACTS)
has been used widely in the reactive power compensation of power system thanks to its fast response.During the manufacturing period of STATCOM
each function of full-bridge sub module must be tested
in which rated current testing commonly at present is that the power is supplied to the DC side capacitor of the sub-model through the diode rectifier
while a big reactor is connected to the AC side of the sub module.The magnitude of current is adjusted by adjusting the output voltage magnitude of AC side.With this method
only one sub module can be tested at the same time.It is a time consuming and inefficiency process in the batch production of the STATCOM.In this paper
a batch testing method of the sub module is proposed with which a group of sub modules can be tested simultaneously by way of series of the sub-model and addition of grading control algorithm of the sub-model
thus improving significantly the testing efficiency of the submodel and saving labor cost.
关键词
静止同步补偿器(STATCOM)H桥子模块无功补偿
Keywords
static synchronous compensator(STATCOM)H bridge sub modulereactive power compensation