ZHANG YANCHANG, LIU GANG, SHI WEI, et al. Economic Operation Study on Reactive Power Compensation Device of Large PV Power Station. [J]. Power capacitor & reactive power compensation, 2019, 40(3): 41-46.
ZHANG YANCHANG, LIU GANG, SHI WEI, et al. Economic Operation Study on Reactive Power Compensation Device of Large PV Power Station. [J]. Power capacitor & reactive power compensation, 2019, 40(3): 41-46. DOI: 10.14044/j.1674-1757.pcrpc.2019.03.008.
Economic Operation Study on Reactive Power Compensation Device of Large PV Power Station
The type of reactive power compensation device of PV power station is in general divided into SVG+FC or total SVG. As for the large PV power station in the north part of China and in accordance with distribution curve of radiation intensity at the stationsite
such two type of reactive power compensation device as SVG+FC and whole SVG are compared by the comparison in both economic and technical aspects of the whole life period.It is known by the comparison and analysis that for the 100 MW PV power station model established in the north region
the choice of SVG+FC is preferable for the reactive power compensation due to large percentage rate of by no radiation intensity at night
in which the choice of FC capacity is the fixed capacity of reactive compensation of the whole PV power station. From point view of the technology
since the fault rate of SVG is a bit higher
the choice of SVG+FC is more reliable for the PV power station.The study result can be sued as reference for the related industry and research institute rated to the design to the PV powerstation.
关键词
光伏电站全寿命周期光强辐射强度分布曲线无功补偿装置
Keywords
PV power stationtotal life cycleintensity distribution curve of light intensity radiationreactive power compensation device
Discussion on the Protection Setting of Reactive Compensation Equipment
Analysis and Solutions of Abnormal Heat Phenomenon of Reactor in Reactive Power Compensation Device
Study on Selection of Reactive Power Compensation Device for Wind Farm
Study on the Control Strategy of Reactive Power Voltage Stability of Grid-connected PV System
Related Author
ZHANG Li
AN Ge
NAN Jun-bo
ZHAGN Yanchang
SHI Wei
WANG Jie
CHEN Ling
LIU Zhongyuan
Related Institution
Shaanxi Electric Engineering Consulting & Survey Design Co.,Ltd.
Xi’an XD Power Capacitor Co., Ltd.
School of Electrical Engineering,Xinjiang University,Engineering Research Center of Ministry of Education for Renewable Energy Power Generation & Grid Technology
State Grid Ningxia Electrical Power Maintenance Company