WANG QIANQIAN, XIE YAOPING. Research on Accuracy Assessment of CVT Under Gradual Error. [J]. Power capacitor & reactive power compensation, 2021, 42(6): 121-126.
DOI:
WANG QIANQIAN, XIE YAOPING. Research on Accuracy Assessment of CVT Under Gradual Error. [J]. Power capacitor & reactive power compensation, 2021, 42(6): 121-126. DOI: 10.14044/j.1674-1757.pcrpc.2021.06.018.
Research on Accuracy Assessment of CVT Under Gradual Error
摘要
准确度试验是CVT抽检测试项目的重要一环
目前在线监测方法对于异常状态无法准确地考核
为此
提出了一种适用于渐变性误差下的CVT准确度考核方法。本文搭建了CVT计量误差对比测试平台CVT
结合传统主元和改进主元分析的方法
对温度、频率等干扰下的渐变性误差进行了评估。试验表明
改进主元分析的方法可自动调节Q阈值
评估精确度较高
优于传统主元分析方法;随着温度的升高
CVT比差会减小
角差会增大;随着频率的增加
CVT比差和角差均减小。本文方法为渐变性误差下CVT的准确度测试提供一定的技术支撑。
Abstract
Accuracy test is important part of sampling test for CVT. At present
the online monitoring method cannot accurately assess the abnormal state. Therefore
the accuracy assessment method of CVT
which is suitable for gradual error
is proposed. In this paper
the test platform of measurement error and comparison for CVT is set up. The gradual error under temperature
frequency and other disturbances are evaluated in combination with traditional PCA analysis and improved PCA analysis. The test shows that the improved PCA method can automatically adjust Q threshold with higher evaluation accuracy and is better than the traditional PCA method. With the increase of temperature
ratio difference of CVT can decreases and angle difference of CVT can increase.While
with the increase of frequency
both ratio and angle difference of CVT decrease. The method in this paper provides a definite technical support for accuracy assessment of CVT under gradual error.