ZHANG JIAN-JUN, QIN CHAO-YUN. Full Insulation Research and Application on Dry Type Air-core Reactor. [J]. Power capacitor & reactive power compensation, 2011, 32(1): 29-32.
ZHANG JIAN-JUN, QIN CHAO-YUN. Full Insulation Research and Application on Dry Type Air-core Reactor. [J]. Power capacitor & reactive power compensation, 2011, 32(1): 29-32. DOI: 10.14044/j.1674-1757.pcrpc.2011.01.004.
干式空心电抗器全绝缘的研究与应用
摘要
目前
国内电网运行的干式空心电抗器受限于变电站场地限制
多采用叠装形式安装
从而易发生由于小动物、鸟类造成的设备相间短路事故
引起设备损坏、停运;为此
通过对35 kV及以下干式空心电抗器全绝缘的研究与应用工作
可以有效避免由于小动物、鸟类造成的设备事故的发生
保证电网的安全稳定运行。
Abstract
At present
the dry type air-core reactors applied in domestic power grid mostly uses the stack-up pattern installment due to space limitation of substation
thus easily leading to short circuit between phases
damage or shutdown of equipments because of small animals or birds.Therefore full-insulation research and application of dry type air-core reactors at 35 kV and below can effectively avoid equipment accidents caused by small animals or birds and assure safe and stable operation of the electric network.
关键词
干式空心电抗器全绝缘研究应用
Keywords
dry type air-core reactorfull insulationresearchapplication