LI ZHAO-LIN, CHEN SHONG, FENG CHUN-LIN. Comparison Study on AC and DC Breakdown Voltage Ratio of the Power Capacitor Dielectric. [J]. Power capacitor & reactive power compensation, 2011, 32(2): 38-42.
LI ZHAO-LIN, CHEN SHONG, FENG CHUN-LIN. Comparison Study on AC and DC Breakdown Voltage Ratio of the Power Capacitor Dielectric. [J]. Power capacitor & reactive power compensation, 2011, 32(2): 38-42. DOI: 10.14044/j.1674-1757.pcrpc.2011.02.010.
The field strength distribution of series dielectric in DC electric field is
unlike in AC electric field
mainly decided by their volume resistivity ratio in addition to the enhancement effect of space-charge.The liquid and solid dielectric normally for power capacitor
due to obvious difference in its relative permittivity and volume resistivity
make unavoidably influence on the application in DC electric field and AC 50 Hz electric field after their recombination.Through the test and study of liquid
solid and recombination dielectrics under DC and AC breakdown voltage
preliminary knowledge about the feature difference of same kind of material in different electric field is obtained so to provide fundamental reference data for the development of DC power capacitor.
关键词
电容器介质直流电场交流电场等效值直流电压极性
Keywords
dielectric for power capacitorDC electric fieldAC electric fieldequivalent valueDC voltagepolarity