HUANG YING1, LI ZHI-YUAN2, HUANG GUO-XING2 LIANG CONG3, et al. Study on the Test Methods to the Sound Power Level of Audible Noise from Power Capacitor. [J]. Power capacitor & reactive power compensation, 2013, 34(3): 28-32.
HUANG YING1, LI ZHI-YUAN2, HUANG GUO-XING2 LIANG CONG3, et al. Study on the Test Methods to the Sound Power Level of Audible Noise from Power Capacitor. [J]. Power capacitor & reactive power compensation, 2013, 34(3): 28-32. DOI: 10.14044/j.1674-1757.pcrpc.2013.03.013.
电力电容器可听噪声声功率级测试方法的研究
摘要
电力电容器是高压直流换流站内主要噪声辐射源之一
对电力电容器可听噪声的测试原理、测试条件、测试方法等问题进行研究是十分必要的。研究表明
在用声压法进行电容器单元的声功率级测定时
为了消除测试环境的声反射等影响造成的非自由场误差
室内测试环境的修正值K应满足K≤2 dB
背景噪声应低于被测电容器单元噪声10 dB;为了减少模型假设引起的近场误差
测点到电容器单元的表面距离应在1 m以上;在测量面上的测点均匀分布时
平均声压级应采用测点数平均法计算
测点分布不均匀时
则应采用面积平均法计算。
Abstract
Power capacitor is one of main noise radiation sources in HVDC converter station and it is necessary to study test principle of audible noise of power capacitor
test condition and method etc.It is shown by the study that when test on the sound power of power capacitor unit through sound pressure method and for eliminating the un-free field error caused by the sound reflection of the testing environment
the correction value K of the indoor test environment shall be smaller or equal to 2 dB and background noise be lower than the noise of measured capacitor unit by 10 dB;In order to reduce the near-field error caused by model assumption
the distance from measured point to surface of the capacitor unit shall be over 1 m;In case of even distribution of measuring point on the measurement surface
average sound pressure level shall be calculated by the point average method and
in case of uneven
by area average method.
关键词
电力电容器声功率测试方法测试条件
Keywords
power capacitorsound powertest methodtest condition