一起220kV CVT二次电压偏高的分析处理
摘要
详细分析了一起CVT二次电压偏高故障的原因。结果表明
由于中压电容C22末端引出线未采用接线鼻子
而是通过铜绞线缠绕并锡焊处理。连接时
由于生产厂家工艺控制不严
末端引出线接线端部有缺陷。长期运行过程中
缺陷逐步扩大最终形成放电
破坏了油室之间的密封结构
造成高压电容C12上部电容元件由于缺油而击穿
引起二次电压升高。最后结合系统运行情况提出了相应的预防措施。
Abstract
In this paper
the cause of higher secondary voltage of one capacitor voltage transformer is analyzed in detail.It is shown that since medium-voltage capacitor C 22 terminal outlet wire without using terminal block
but using copper wire winding and soldering treatment
the manufacturer is not strict in the process control in the connection
wiring end of outlet wire has defects.The defects is developed gradually and finally formed into discharge during long term operation
which damages sealing structure between oil compartments
causes breakdown of C 12 upper capacitor element due to lack of oil and then causes secondary voltage rise.Moreover
corresponding preventive measure is proposed based on system operation.