PANG YUNTING, MA LEI, LU YONG, et al. Study on Accurate Online Detection Method of Super Capacitor for Variable Pitch System. [J]. Power capacitor & reactive power compensation, 2016, 37(4): 47-50.
PANG YUNTING, MA LEI, LU YONG, et al. Study on Accurate Online Detection Method of Super Capacitor for Variable Pitch System. [J]. Power capacitor & reactive power compensation, 2016, 37(4): 47-50. DOI: 10.14044/j.1674-1757.pcrpc.2016.04.009.
变桨用超级电容器容值的精确在线检测研究
摘要
针对风力发电机组变桨系统中超级电容器组的特殊工况
提出了1种超级电容器容值的精确在线检测方法。通过增加对容值、充/放电电阻值的温度补偿系数
有效克服了模拟量测量精度对容值检测的影响
提高了超级电容器容值的检测精度。实验证明本方法所提检测方式的误差为0.5%
且无需增加硬件设备
操作方便
降低了风电机组运维工作的难度。
Abstract
As for the special condition of super capacitor bank in the variable pitch system of wind turbine
a kind of accurate an online detection method for the capacitance of super capacitor is propo-sed. The infl- uence of simulated measurement accuracy on capacitance is overcome efficiently by way of adding temperature compensation coefficient of capacitance and charging / discharging resistance and the capacitance detection accuracy of the super capacitor is improved. It is shown by the experiment that the error of the detection mode by the proposed method is 0. 5 % without adding hardware equip-ment is convenient in operation and reduces the difficulty of the wind turbine in operation and maintenance.
关键词
变桨系统后备电源超级电容检测精度温度补偿
Keywords
variable pitch systembackup power supplysuper capacitordetection precisiontemperature compensation