ZHU XIAOHANG, CHEN HONGKUN, HU PAN. Reactive Power Compensation Scheme for Arc Furnace With Consideration of Power Quality Constraints. [J]. Power capacitor & reactive power compensation, 2017, 38(1): 28-34.
ZHU XIAOHANG, CHEN HONGKUN, HU PAN. Reactive Power Compensation Scheme for Arc Furnace With Consideration of Power Quality Constraints. [J]. Power capacitor & reactive power compensation, 2017, 38(1): 28-34. DOI: 10.14044/j.1674-1757.pcrpc.2017.01.005.
As for such problem as voltage fluctuation and flicker
three-phase unbalance and harmonic due to AC arc furnace
the reactive power compensation allocation calculation method with consideration of power quality constraints is proposed and is controlled by joint operation compensation scheme by the use of static var compensator(SVC)and static synchronous compensator(STATCOM). The data of actual project of certain arc furnace at Hubei Tianmen is taken as reference
corresponding compensation allocation scheme is given respectively in accordance with three sets of different power quality grade requirement
the power supply system model of three-phase arc furnace based on the above compensation scheme is set up
and its simulation and verification are made. It is shown by the simulation result that the proposed reactive power compensation scheme can solve effectively the power quality problem and
on the perquisite of the controlling result
reduce the investment cost of the scheme and improve the economic efficiency of steel enterprise.
关键词
电能质量交流电弧炉无功补偿
Keywords
power qualityAC arc furnacereactive power compensation