FAN ZHEYUN, AIKEPAER YIMITI, GOU CHENG, et al. Improved Method for the Heating of Grounding System of Dry Type Reactor. [J]. Power capacitor & reactive power compensation, 2018, 39(6): 103-107.
FAN ZHEYUN, AIKEPAER YIMITI, GOU CHENG, et al. Improved Method for the Heating of Grounding System of Dry Type Reactor. [J]. Power capacitor & reactive power compensation, 2018, 39(6): 103-107. DOI: 10.14044/j.1674-1757.pcrpc.2018.06.021.
一种针对干式电抗器接地系统发热的改进方法
摘要
为了使电抗器支持绝缘子的接地引下线减少发热
本文基于红外测温技术
提出了一种针对干式电抗器接地系统—发热的改进方法
即通过双层接地网切断涡流。实验结果表明
该方法是一种有效可行的改进方法
将改进前与本文改进方法进行对比
双层接地应用于干式电抗器接地系统对抑制该区域接地系统发热获得了更好的效果。
Abstract
For reducing the heating of grounding wire of the support insulator of reactor
in this paper
a kind of improved method for the heating of grounding system of dryty pereactor is proposed based on the infrared temperature measurement technology
the eddy current is cut off by double grounding grid. It is shown by theexperimental result that the method is an effective and feasible improved method and
through comparisonof the method before and after improvement
that application of the double layer to the grounding system ofdry type reactor can obtain better effect in suppressing the heating of the grounding system of the area.
关键词
干式电抗器接地发热双层接地
Keywords
dry type reactorgroundingheatingdouble layer grounding grid