1. 云南电网有限责任公司电网规划研究中心
2. 浙江大学电气工程学院
纸质出版日期:2020,
移动端阅览
[1]游广增,肖亮,李玲芳,朱欣春,杨健,武兴龙,王国腾,徐政.典型高比例新能源地区电网采用柔性直流技术进行加强的方案设计方法[J].电力电容器与无功补偿,2020,41(01):142-150+157.
YOU GUANGZENG, XIAO LIANG, LI LINGFANG, et al. Design Method for Reinforcement Scheme of Typical Regional Power Grid with High Proportion of Renewable Energy Using VSC-HVDC Technology. [J]. Power capacitor & reactive power compensation, 2020, 41(1): 142-150.
[1]游广增,肖亮,李玲芳,朱欣春,杨健,武兴龙,王国腾,徐政.典型高比例新能源地区电网采用柔性直流技术进行加强的方案设计方法[J].电力电容器与无功补偿,2020,41(01):142-150+157. DOI: 10.14044/j.1674-1757.pcrpc.2020.01.024.
YOU GUANGZENG, XIAO LIANG, LI LINGFANG, et al. Design Method for Reinforcement Scheme of Typical Regional Power Grid with High Proportion of Renewable Energy Using VSC-HVDC Technology. [J]. Power capacitor & reactive power compensation, 2020, 41(1): 142-150. DOI: 10.14044/j.1674-1757.pcrpc.2020.01.024.
本文提出了典型高比例新能源地区电网采用柔性直流输电(VSC-HVDC)技术进行加强的方案设计方法和流程。结合高比例新能源地区电网的特征
首先分析了制约其安全稳定运行的3个主要因素;然后从加强电网安全稳定性的角度
以云南楚雄电网为例设计了采用VSC-HVDC的两种加强方案
进一步提炼出了高比例新能源地区电网采用VSC-HVDC进行加强的选址和定容方法
并且归纳了3个衡量VSC-HVDC加强方案优劣的技术性指标
分别是线路负载率、电压水平以及VSC接入点强度。计算结果表明
按照所提的方案设计方法
两种VSC-HVDC加强方案均能将过载严重的线路负载率降低至90%以下
很好地解决了新能源大发方式下电磁环网的线路过载问题;此外
采用VSC-HVDC技术对地区电网进行加强后
故障期间楚雄地区关键节点的电压水平提升了10%~19%
有效地提升了系统的电压水平。
A design method for the reinforcement scheme of the typical regional power grid with high proportion of renewable energy using VSC-HVDC technology is proposed in this paper.Considering the characteristics of the regional power grid with high proportion of renewable energy
three main factorsres tricting its safe and stable operation is analyzed firstly.Then from the perspective of enhancing the safe and stable operation of power grids
two VSC-HVDC reinforcement schemes are designed by taking Chuxiong Power Grid in Yunnan as an example.A method to determine the location and capacity of the VSC-HVDC system in the regional power grid with high proportion of renewable energy is proposed further and three technical indexes to evaluate the VSC-HVDC schemes
namely line load rate
voltage level and the strength of the VSC connection point are summarized.It is shown by the calculation resultthat following the proposed design methodology
the two VSC-HVDC schemes can reduce the line load rate of those lines with severe overload problems to less than 90%
which is a good solution to the line overload problem of the electromagnetic loop networks with high generation of renewable energy;With the VSCHVDC technology
the voltage level of key buses in Chuxiong area is increased by 10%-19% during the faulted period
effectively increasing the voltage level of the system.
高比例新能源柔性直流输电系统加强方案选址和定容评价指标
highproportionofrenewableenergyVSC-HVDCsystemreinforcementschemedetermination of locationandcapacityevaluation indexes
0
浏览量
94
下载量
3
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621