LEI MINGDONG, ZHANG SHIHONG, XU KE, et al. Study on Fault Location Method of Bridge Differential Unbalanced Protection Capacitor Bank Based on Relative Current Detection. [J]. Power capacitor & reactive power compensation, 2021, 42(1): 1-5.
LEI MINGDONG, ZHANG SHIHONG, XU KE, et al. Study on Fault Location Method of Bridge Differential Unbalanced Protection Capacitor Bank Based on Relative Current Detection. [J]. Power capacitor & reactive power compensation, 2021, 42(1): 1-5. DOI: 10.14044/j.1674-1757.pcrpc.2021.01.001.
基于相对电流检测的桥差不平衡保护电容器组故障定位方法研究
摘要
介绍桥差不平衡保护电容器组的结构和原理。提出一种基于相对电流检测的故障定位方法
解决桥差不平衡保护电容器组的故障定位问题。设计了一种新型的故障定位装置
当电容器组存在电容器元件损坏故障时
通过捕捉相对电流值的突变
可以识别微小故障、对称故障
并且可以判定故障区域至H桥的1/4区域。搭建H桥模型并进行仿真分析
结果认为该方法可以实现以上功能。
Abstract
The structure and principle of bridge differential unbalanced protection capacitor bank are introduced. A kind of fault location method based on relative current detection is proposed to solve the problem of fault location for bridge differential unbalanced protection capacitor banks. A new type of fault location device is designed. In case of damage fault of capacitor element of capacitor bank
the minor and symmetrical fault can be identified by way of capturing sudden change of relative current and the fault area can be judged in 1/4 area of H bridge. The H-bridge model is set up for simulation and analysis and it is thought that the method can achieve above functions.
关键词
桥差不平衡保护电容器组相对电流检测仿真分析
Keywords
bridge differential unbalanced protectioncapacitor bankrelative current detectionsimulation analysis